Overview of Some of AET's Service and After-Sales Assignments |
||||
---|---|---|---|---|
Year |
Plant |
Fuel Type |
Fuel HeatInput |
Scope of Delivery |
2019 |
Demolition wood (A1-A2) and dust | 65 MWth | Replacement of safety PLC | |
2018 |
Eramet (NO) |
CO gas | 55 MWth | Replacement of SCADA |
2018 | Clean wood, distillery by-product (draff) | 34 MWth | Maintenance of fuel dryer | |
2018 -2034 |
Clean wood | 63 MWth | 16½ year O&M contract | |
2018 |
Preem Refinery (SE) |
Process gas | 80 MWth | Replacement of superheaters |
2018 | Kronospan-Novopan (DK) | Waste wood, sander dust | 27 MWth | Replacement of superheaters |
2017 | Lisbjerg (DK) | Straw | 110 MWth | Commissioning |
2017 |
International Paper (FR) |
Clean wood, sludge | 50 MWth | Test of SNCR DeNOx possibility and efficiency |
2017 | Randers Verdo (DK) | Biomass, pellets, shea nuts, etc. | 2x95 MWth | Consulting regarding CO and NOx |
2017 -2037 |
Waste wood | 125 MWth |
20 year O&M contract |
|
2016 | Biomass, coal and oil | Up to 106 MWth | Fuel conversion to biomass/coal/oil from coal/oil, with AET Combi Spreader | |
2016 |
TripleNine, Thyborøn (DK) |
Coal | 2 x 20 MWth | AET SNCR DeNOx plant |
2016 | Demolition wood (A1-A2) and dust | 65 MWth | Replacement of SH 1 | |
2016 |
Morsø Fjernvarme (DK) |
Oil and gas | several | SCADA for several boiler plants, including emergency back-up plants |
2016 |
Eramet (NO) |
CO gas | 55 MWth | SCADA and PLC control for boiler and steam turbine. |
2015 |
International paper (FR) |
Clean wood, sludge | 50 MWth |
CO and NOx measurment. Fly ash re-injection system. AET system for fuel dosing |
2015 | Dust-fired | 30 MWth | Superheater replacement | |
2015 | Clean wood, demolition wood (A1-A2) and dust | 46 MWth | Economiser replacement | |
2015 |
Cofely BCN (FR) |
Clean wood, forestry wood | 55 MWth |
SNCR DeNOx plant |
2014 |
Kronospan-Novopan (DK) |
Waste wood, sander dust |
27 MWth |
SNCR DeNOx plant |
2014 | Clean wood, energy crops | 50 MWth | District heating system, including tail end heat exchanger | |
2013 -> | Clean wood, energy crops | 50 MWth | Regular inspection | |
2012 -2013 |
Clean wood and dust/coal |
2x95 MWth |
Redesign and supply of new superheater 2 & 3 |
|
2012 -> | Clean wood, forestry wood | 55 MWth | Regular inspection | |
2012 | Forest Wood, clean rec. waste wood | 48 MWth | Supply of new superheater 4 | |
2011 |
Clean wood, demolition wood (A1-A2) and dust |
27 MWth |
Upgrade of boiler, supply steam turbine and steam/water cycle |
|
2011 |
Vattenfall (DK) |
Coal and 20% biomass |
800 MWth |
Pre-project and tender material for conversion to app. 20% biomass |
2011 |
Bioener-Fynsværket (DK) |
Straw |
150 MWth |
Erection and commissioning |
2010 |
Waste wood, sander dust |
100 MWth |
Measurement of CO formation and identify CO reduction means |
|
2010 |
Østkraft (DK) |
Biomass |
120 MWth |
Performance calculations for fuel conversion |
2009 |
Eye Power Station (UK) |
Poultry litter |
48 MWth |
Measurement of CO formation and identify CO reduction means |
2008 |
Tinfos (NO) |
CO gas |
55 MWth |
Energy optimisation |
2008 |
Forest Wood, clean rec. waste wood |
48 MWth |
Regular inspection |
|
2008 |
Invista (UK) |
Coal |
2x45 MWth |
Furnace measurement (prove WID compliant) |
2008 |
Tinfos (NO) |
CO gas | 55 MWth | Server control and upgrade |
2007 |
Clean wood |
48 MWth |
6 year O&M contract |
|
2007 |
Kronospan-Novopan (DK) |
Waste wood, sander dust |
27 MWth |
Measurement of CO formation and identify CO reduction means |
2006 -> | Clean wood | 35 MWth | Regular inspection | |
2005 |
CP Kelko (DK) |
Natural gas/Coal |
50 MWth |
Energy optimisation |
2005 |
Demolition wood (A1-A2) |
70 MWth |
Ash re-injecting system/fly ash transport |
|
2005 |
Clean wood, demolition wood (A1-A2) and dust |
46 MWth |
Thermal oil heater replacement |
|
2005 -> |
Clean wood, demolition wood (A1-A2) and dust |
26 MWth | Regular inspection | |
2004 |
Demolition wood (A1-A2) and dust |
65 MWth |
Inconel furnace cladding |
|
2004 -> |
Demolition wood (A1-A2) and dust |
65 MWth |
Regular inspection | |
2003 |
Roulunds Fabrikker (DK) |
Gas |
20 MWth |
Energy optimisation |
2003 |
Randers Verdo (DK) |
Biomass, pellets, shea nuts, etc. | 2x95 MWth | AET Dust-firing System |
2002 |
Akafa (DK) |
Oil/gas |
20 MWth |
Energy optimisation |
2002 -> |
Demolition wood (A1-A2) and dust |
100 MWth |
Regular inspection |
|
2001 -> |
Demolition wood (A1-A2) and dust |
60 MWth |
Regular inspection |
|
1999 |
Demolition wood (A1-A2) and dust |
46 MWth | AET Dust Firing System | |
1998 -> |
DuPont (N. Ireland) |
Coal and tar |
2x45 MWth |
Regular inspection |
1998 |
Demolition wood (A1-A2) and dust |
100 MWth |
Combustion optimisation |
|
1998 -> |
British Sugar, Cantley (UK) |
Coal (and oil) |
50 MWth |
Regular inspection |